| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| CloudForms Management Engine before 5.8 includes a default SSL/TLS certificate. |
| D-Link DVG-N5402SP with firmware W1000CN-00, W1000CN-03, or W2000EN-00 has a default password of root for the root account and tw for the tw account, which makes it easier for remote attackers to obtain administrative access. |
| A hard-coded account named 'upgrade' in Fortinet FortiWLM 8.3.0 and lower versions allows a remote attacker to log-in and execute commands with 'upgrade' account privileges. |
| On the TP-Link TL-SG108E 1.0, there is a hard-coded ciphering key (a long string beginning with Ei2HNryt). This affects the 1.1.2 Build 20141017 Rel.50749 firmware. |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords. |
| WN-G300R3 firmware version 1.0.2 and earlier uses hardcoded credentials which may allow an attacker that can access the device to execute arbitrary code on the device. |
| WN-AX1167GR firmware version 3.00 and earlier uses hardcoded credentials which may allow an attacker that can access the device to execute arbitrary code on the device. |
| Toshiba Home gateway HEM-GW16A firmware HEM-GW16A-FW-V1.2.0 and earlier, Toshiba Home gateway HEM-GW26A firmware HEM-GW26A-FW-V1.2.0 and earlier uses hard-coded credentials, which may allow attackers to perform operations on device with administrative privileges. |
| In net.MCrypt in the "Diary with lock" (aka WriteDiary) application 4.72 for Android, hardcoded SecretKey and iv variables are used for the AES parameters, which makes it easier for attackers to obtain the cleartext of stored diary entries. |
| The getUserzoneCookie function in Kaltura before 13.2.0 uses a hardcoded cookie secret to validate cookie signatures, which allows remote attackers to bypass an intended protection mechanism and consequently conduct PHP object injection attacks and execute arbitrary PHP code via a crafted userzone cookie. |
| The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG599 device, when IP Passthrough mode is not used, configures WAN access to a caserver https service with the tech account and an empty password, which allows remote attackers to obtain root privileges by establishing a session on port 49955 and then installing new software, such as BusyBox with "nc -l" support. |
| The Java keystore in all versions and editions of Rapid7 Nexpose prior to 6.4.50 is encrypted with a static password of 'r@p1d7k3y5t0r3' which is not modifiable by the user. The keystore provides storage for saved scan credentials in an otherwise secure location on disk. |
| MEDHOST Connex contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. Connex utilizes an IBM i DB2 user account for database access. The account name is HMSCXPDN. Its password is hard-coded in multiple places in the application. Customers do not have the option to change this password. The account has elevated DB2 roles, and can access all objects or database tables on the customer DB2 database. This account can access data through ODBC, FTP, and TELNET. Customers without Connex installed are still vulnerable because the MEDHOST setup program creates this account. |
| MEDHOST Connex contains a hard-coded Mirth Connect admin credential that is used for customer Mirth Connect management access. An attacker with knowledge of the hard-coded credential and the ability to communicate directly with the Mirth Connect management console may be able to intercept sensitive patient information. The admin account password is hard-coded as $K8t1ng throughout the application, and is the same across all installations. Customers do not have the option to change the Mirth Connect admin account password. The Mirth Connect admin account is created during the Connex install. The plaintext account password is hard-coded multiple times in the Connex install and update scripts. |
| The Cisco AMP For Endpoints application allows an authenticated, local attacker to access a static key value stored in the local application software. The vulnerability is due to the use of a static key value stored in the application used to encrypt the connector protection password. An attacker could exploit this vulnerability by gaining local, administrative access to a Windows host and stopping the Cisco AMP for Endpoints service. Cisco Bug IDs: CSCvg42904. |
| A Use of Hard-Coded Cryptographic Key issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded private cryptographic keys that may allow an attacker to decrypt traffic from any other source. |
| An issue was discovered on the D-Link DWR-932B router. There is a hardcoded WPS PIN of 28296607. |
| An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234. |
| Backup archives were found to be encrypted with a static password across different installations, which suggest the same password may be used in all virtual appliance instances of Trend Micro Deep Discovery Director 1.1. |
| Multiple hardcoded credentials in Xsuite 2.x. |