Search Results (2396 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-28139 2026-04-15 8.8 High
The www-data user can elevate its privileges because sudo is configured to allow the execution of the mount command as root without a password. Therefore, the privileges can be escalated to the root user. The risk has been accepted by the vendor and won't be fixed in the near future.
CVE-2024-28140 2026-04-15 6.1 Medium
The scanner device boots into a kiosk mode by default and opens the Scan2Net interface in a browser window. This browser is run with the permissions of the root user. There are also several other applications running as root user. This can be confirmed by running "ps aux" as the root user and observing the output.
CVE-2024-29011 1 Sonicwall 1 Global Management System 2026-04-15 7.5 High
Use of hard-coded password in the GMS ECM endpoint leading to authentication bypass vulnerability. This issue affects GMS: 9.3.4 and earlier versions.
CVE-2024-29978 2026-04-15 5.9 Medium
User passwords are decrypted and stored on memory before any user logged in. Those decrypted passwords can be retrieved from the coredump file. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References].
CVE-2024-35783 1 Siemens 6 Simatic Batch, Simatic Information Server, Simatic Pcs7 and 3 more 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
CVE-2024-3625 1 Redhat 1 Mirror Registry 2026-04-15 7.3 High
A flaw was found in Quay, where Quay's database is stored in plain text in mirror-registry on Jinja's config.yaml file. This issue leaves the possibility of a malicious actor with access to this file to gain access to Quay's Redis instance.
CVE-2024-38427 1 Color 1 Demoiccmax 2026-04-15 8.8 High
In International Color Consortium DemoIccMAX before 85ce74e, a logic flaw in CIccTagXmlProfileSequenceId::ParseXml in IccXML/IccLibXML/IccTagXml.cpp results in unconditionally returning false.
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2024-45283 2026-04-15 6 Medium
SAP NetWeaver AS for Java allows an authorized attacker to obtain sensitive information. The attacker could obtain the username and password when creating an RFC destination. After successful exploitation, an attacker can read the sensitive information but cannot modify or delete the data.
CVE-2024-46959 1 Runofast 1 Cloudcam Firmware 2026-04-15 6.5 Medium
runofast Indoor Security Camera for Baby Monitor has a default password of password for the root account. This allows access to the /stream1 URI via the rtsp:// protocol to receive the video and audio stream.
CVE-2022-38695 2026-04-15 7.8 High
In BootRom, there's a possible unchecked command index. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2025-13911 2 Inductiveautomation, Microsoft 2 Ignition, Windows 2026-04-15 6.4 Medium
The vulnerability affects Ignition SCADA applications where Python scripting is utilized for automation purposes. The vulnerability arises from the absence of proper security controls that restrict which Python libraries can be imported and executed within the scripting environment. The core issue lies in the Ignition service account having system permissions beyond what an Ignition privileged user requires. When an authenticated administrator uploads a malicious project file containing Python scripts with bind shell capabilities, the application executes these scripts with the same privileges as the Ignition Gateway process, which typically runs with SYSTEM-level permissions on Windows. Alternative code execution patterns could lead to similar results.
CVE-2022-38694 2026-04-15 7.8 High
In BootRom, there is a possible unchecked write address. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2024-6694 2026-04-15 2.7 Low
The WP Mail SMTP plugin for WordPress is vulnerable to information exposure in all versions up to, and including, 4.0.1. This is due to plugin providing the SMTP password in the SMTP Password field when viewing the settings. This makes it possible for authenticated attackers, with administrative-level access and above, to view the SMTP password for the supplied server. Although this would not be useful for attackers in most cases, if an administrator account becomes compromised this could be useful information to an attacker in a limited environment.
CVE-2022-38691 1 Unisoc 4 Sc9863a, T310, T610 and 1 more 2026-04-15 7.8 High
In BootROM, there is a possible missing validation for Certificate Type 0. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2024-8903 2026-04-15 N/A
Local active protection service settings manipulation due to unnecessary privileges assignment. The following products are affected: Acronis Cyber Protect Cloud Agent (Windows, macOS) before build 38565.
CVE-2024-42197 1 Hcltech 1 Workload Scheduler 2026-04-15 5.5 Medium
HCL Workload Scheduler stores user credentials in plain text which can be read by a local user.
CVE-2025-11193 1 Lenovo 2 Tablet, Yoga 2026-04-15 5.5 Medium
A potential vulnerability was reported in some Lenovo Tablets that could allow a local authenticated user or application to gain access to sensitive device specific information.
CVE-2024-28325 1 Asus 1 Rt-n12\+ B1 2026-04-15 6.1 Medium
Asus RT-N12+ B1 router stores credentials in cleartext, which could allow local attackers to obtain unauthorized access and modify router settings.
CVE-2024-22017 2 Nodejs, Redhat 2 Nodejs, Enterprise Linux 2026-04-15 7.3 High
setuid() does not affect libuv's internal io_uring operations if initialized before the call to setuid(). This allows the process to perform privileged operations despite presumably having dropped such privileges through a call to setuid(). This vulnerability affects all users using version greater or equal than Node.js 18.18.0, Node.js 20.4.0 and Node.js 21.