| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements. |
| An Insufficiently Protected Credentials issue was discovered in LOYTEC LVIS-3ME versions prior to 6.2.0. The application does not sufficiently protect sensitive information from unauthorized access. |
| kedpm 0.5 and 1.0 creates a history file in ~/.kedpm/history that is written in cleartext. All of the commands performed in the password manager are written there. This can lead to the disclosure of the master password if the "password" command is used with an argument. The names of the password entries created and consulted are also accessible in cleartext. |
| The Reporting feature in X-Pack in versions prior to 5.5.2 and standalone Reporting plugin versions versions prior to 2.4.6 had an impersonation vulnerability. A user with the reporting_user role could execute a report with the permissions of another reporting user, possibly gaining access to sensitive data. |
| The Kickbase GmbH "Kickbase Bundesliga Manager" app before 2.2.1 -- aka kickbase-bundesliga-manager/id678241305 -- for iOS is vulnerable to a credentials leak due to transmitting a username and password in cleartext from client to server during registration and authentication. |
| An issue was discovered on Mimosa Client Radios before 2.2.3. In the device's web interface, there is a page that allows an attacker to use an unsanitized GET parameter to download files from the device as the root user. The attacker can download any file from the device's filesystem. This can be used to view unsalted, MD5-hashed administrator passwords, which can then be cracked, giving the attacker full admin access to the device's web interface. This vulnerability can also be used to view the plaintext pre-shared key (PSK) for encrypted wireless connections, or to view the device's serial number (which allows an attacker to factory reset the device). |
| Cleartext password storage exists on Peplink Balance 305, 380, 580, 710, 1350, and 2500 devices with firmware before fw-b305hw2_380hw6_580hw2_710hw3_1350hw2_2500-7.0.1-build2093. The files in question are /etc/waipass and /etc/roapass. In case one of these devices is compromised, the attacker can gain access to passwords and abuse them to compromise further systems. |
| Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitive information via unspecified vectors. |
| PostgreSQL versions before 9.2.22, 9.3.18, 9.4.13, 9.5.8 and 9.6.4 are vulnerable to authorization flaw allowing remote authenticated attackers to retrieve passwords from the user mappings defined by the foreign server owners without actually having the privileges to do so. |
| A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext. |
| tpm2-tools versions before 1.1.1 are vulnerable to a password leak due to transmitting password in plaintext from client to server when generating HMAC. |
| An attacker can decrypt the Ovarro TBox login password by communication capture and brute force attacks. |
| Pentaminds CuroVMS v2.0.1 was discovered to contain exposed credentials. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure. |
| The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently. |
| An attacker with physical access to the host can extract the secrets from the registry and create valid JWT tokens for the Fresenius Kabi Vigilant MasterMed version 2.0.1.3 application and impersonate arbitrary users. An attacker could manipulate RabbitMQ queues and messages by impersonating users. |
| Philips Vue PACS versions 12.2.x.x and prior transmits or stores authentication credentials, but it uses an insecure method susceptible to unauthorized interception and/or retrieval. |
| The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00. |
| A malicious actor having access to the exported configuration file may obtain the stored credentials and thereby gain access to the protected resource. If the same passwords were used for other resources, further such assets may be compromised. |
| An attacker with weak credentials could access the TCP port via an open FTP port, allowing an attacker to read sensitive files and write to remotely executable directories. |