| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Unchecked return value in SDM firmware for Intel(R) Stratix 10 and Intel(R) Agilex 7 FPGAs before version 23.3 may allow an authenticated user to potentially enable denial of service via adjacent access. |
| Smart-tab Android app installed April 2023 or earlier contains an issue with plaintext storage of a password. If this vulnerability is exploited, an attacker with physical access to the device may retrieve the credential information and spoof the device to access the related external service. |
| Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| A vulnerability classified as critical has been found in IROAD X5 Mobile App up to 5.2.5 on Android. Affected is an unknown function of the component API Endpoint. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A flaw was found in grub2 where the grub_extcmd_dispatcher() function calls grub_arg_list_alloc() to allocate memory for the grub's argument list. However, it fails to check in case the memory allocation fails. Once the allocation fails, a NULL point will be processed by the parse_option() function, leading grub to crash or, in some rare scenarios, corrupt the IVT data. |
| Versa SASE Client for Windows versions released between 7.8.7 and 7.9.4 contain a local privilege escalation vulnerability in the audit log export functionality. The client communicates user-controlled file paths to a privileged service, which performs file system operations without impersonating the requesting user. Due to improper privilege handling and a time-of-check time-of-use race condition combined with symbolic link and mount point manipulation, a local authenticated attacker can coerce the service into deleting arbitrary directories with SYSTEM privileges. This can be exploited to delete protected system folders such as C:\\Config.msi and subsequently achieve execution as NT AUTHORITY\\SYSTEM via MSI rollback techniques. |
| Certain hybrid DVR models ((HBF-09KD and HBF-16NK)) from Hunt Electronic have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials. |
| A flaw was found in how Quay's database is stored in plain-text in mirror-registry on the jinja's config.yaml file. This flaw allows a malicious actor with access to this file to gain access to Quay's database. |
| A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.
Other related CVE's are CVE-2025-14095 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required Configuration for Exposure:
Attacker requires physical access to the analyzer.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. |
| An issue in Debezium Community debezium-ui v.2.5 allows a local attacker to execute arbitrary code via the refresh page function. |
| Argo Events is an event-driven workflow automation framework for Kubernetes. A user with permission to create/modify EventSource and Sensor custom resources can gain privileged access to the host system and cluster, even without having direct administrative privileges. The EventSource and Sensor CRs allow the corresponding orchestrated pod to be customized with spec.template and spec.template.container (with type k8s.io/api/core/v1.Container), thus, any specification under container such as command, args, securityContext , volumeMount can be specified, and applied to the EventSource or Sensor pod. With these, a user would be able to gain privileged access to the cluster host, if he/she specified the EventSource/Sensor CR with some particular properties under template. This vulnerability is fixed in v1.9.6. |
| The SIMPLE.ERP client stores superuser password in a recoverable format, allowing any authenticated SIMPLE.ERP user to escalate privileges to a database administrator.
This issue affect SIMPLE.ERP from 6.20 through 6.30. Only the 6.30 version received a patch 6.30@a03.9, which removed the vulnerability. Versions 6.20 and 6.25 remain unpatched. |
| Beward Intercom 2.3.1 contains a credentials disclosure vulnerability that allows local attackers to access plain-text authentication credentials stored in an unencrypted database file. Attackers can read the BEWARD.INTERCOM.FDB file to extract usernames and passwords, enabling unauthorized access to IP cameras and door stations. |
| A vulnerability was found in shsuishang ShopSuite ModulithShop up to 45a99398cec3b7ad7ff9383694f0b53339f2d35a. Affected by this issue is some unknown functionality of the component RSA/OAuth2/Database. The manipulation results in hard-coded credentials. The attack can be executed remotely. The exploit has been made public and could be used. This product implements a rolling release for ongoing delivery, which means version information for affected or updated releases is unavailable. |
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). |
| A vulnerability was found in Teledyne FLIR FB-Series O and FLIR FH-Series ID 1.3.2.16. It has been classified as problematic. This affects an unknown part. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| CWE-250: Execution with Unnecessary Privileges |
| Software GmbH Agorum core open v11.9.2 & v11.10.1 was discovered to store credentials in plaintext. |
| Clash Verge Rev thru 2.2.3 (fixed in 2.3.0) forces the installation of system services(clash-verge-service) by default and exposes key functions through the unauthorized HTTP API `/start_clash`, allowing local users to submit arbitrary bin_path parameters and pass them directly to the service process for execution, resulting in local privilege escalation. |
| The password is empty in the initial configuration of ACERA 9010-08 firmware v02.04 and earlier, and ACERA 9010-24 firmware v02.04 and earlier. An unauthenticated attacker may log in to the product with no password, and obtain and/or alter information such as network configuration and user information. The products are affected only when running in non MS mode with the initial configuration. |