Search Results (1542 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-54147 2026-04-15 6.8 Medium
Altair is a GraphQL client for all platforms. Prior to version 8.0.5, Altair GraphQL Client's desktop app does not validate HTTPS certificates allowing a man-in-the-middle to intercept all requests. Any Altair users on untrusted networks (eg. public wifi, malicious DNS servers) may have all GraphQL request and response headers and bodies fully compromised including authorization tokens. The attack also allows obtaining full access to any signed-in Altair GraphQL Cloud account and replacing payment checkout pages with a malicious website. Version 8.0.5 fixes the issue.
CVE-2025-40744 1 Siemens 1 Solid Edge Se2025 2026-04-15 7.5 High
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 11). Affected applications do not properly validate client certificates to connect to License Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.
CVE-2024-45205 1 Ui 1 Unifi 2026-04-15 N/A
An Improper Certificate Validation on the UniFi iOS App managing a standalone UniFi Access Point (not using UniFi Network Application) could allow a malicious actor with access to an adjacent network to take control of this UniFi Access Point. Affected Products: UniFi iOS App (Version 10.17.7 and earlier) Mitigation: UniFi iOS App (Version 10.18.0 or later).
CVE-2024-47258 2026-04-15 8.1 High
2N Access Commander version 2.1 and prior is vulnerable in default settings to Man In The Middle attack due to not verifying certificates of 2N edge devices. 2N has currently released an updated version 3.3 of 2N Access Commander, with added Certificate Fingerprint Verification. Since version 2.2 of 2N Access Commander (released in February 2022) it is also possible to enforce TLS certificate validation.It is recommended that all customers update 2N Access Commander to the latest version and use one of two mentioned practices.
CVE-2024-4762 1 Lenovo 2 Accessories And Display Manager, Display Control Center 2026-04-15 7.8 High
An improper validation vulnerability was reported in the firmware update mechanism of LADM and LDCC that could allow a local attacker to escalate privileges.
CVE-2025-40801 1 Siemens 8 Comos, Nx, Simcenter 3d and 5 more 2026-04-15 8.1 High
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions < V2506.0001), Simcenter System Architect (All versions < V2506.0001), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
CVE-2024-48460 2026-04-15 4.3 Medium
An issue in Eugeny Tabby 1.0.213 allows a remote attacker to obtain sensitive information via the server and sends the SSH username and password even when the host key verification fails.
CVE-2025-30000 2026-04-15 6.7 Medium
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). The affected application does not properly restrict permissions of the users. This could allow a lowly-privileged attacker to escalate their privileges.
CVE-2024-27440 2026-04-15 4.8 Medium
The Toyoko Inn official App for iOS versions prior to 1.13.0 and Toyoko Inn official App for Android versions prior 1.3.14 don't properly verify server certificates, which allows a man-in-the-middle attacker to spoof servers and obtain sensitive information via a crafted certificate.
CVE-2024-6001 1 Lenovo 1 Accessories And Display Manager 2026-04-15 8.1 High
An improper certificate validation vulnerability was reported in LADM that could allow a network attacker with the ability to redirect an update request to a remote server and execute code with elevated privileges.
CVE-2024-41724 2026-04-15 8.7 High
Improper Certificate Validation (CWE-295) in the Gallagher Command Centre SALTO integration allowed an attacker to spoof the SALTO server. This issue affects all versions of Gallagher Command Centre prior to 9.20.1043.
CVE-2024-31955 2026-04-15 4.9 Medium
An issue was discovered in Samsung eMMC with KLMAG2GE4A and KLM8G1WEMB firmware. Code bypass through Electromagnetic Fault Injection allows an attacker to successfully authenticate and write to the RPMB (Replay Protected Memory Block) area without possessing secret information.
CVE-2025-7390 1 Softing 4 Edgeaggregator, Edgeconnector, Opc and 1 more 2026-04-15 9.1 Critical
A malicious client can bypass the client certificate trust check of an opc.https server when the server endpoint is configured to allow only secure communication.
CVE-2025-0501 2026-04-15 7.5 High
An issue in the native clients for Amazon WorkSpaces (when running PCoIP protocol) may allow an attacker to access remote sessions via man-in-the-middle.
CVE-2025-65753 1 Gryphon 1 Guardian Gryphon 2026-04-15 7.5 High
An issue in the TLS certification mechanism of Guardian Gryphon v01.06.0006.22 allows attackers to execute commands as root.
CVE-2025-60022 2026-04-15 N/A
Improper certificate validation vulnerability exists in 'デジラアプリ' App for iOS prior to ver.80.10.00. If this vulnerability is exploited, a man-in-the-middle attack may allow an attacker to eavesdrop on and/or tamper with an encrypted communication.
CVE-2025-40800 1 Siemens 6 Comos, Nx, Simcenter 3d and 3 more 2026-04-15 7.4 High
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
CVE-2025-54470 1 Suse 1 Neuvector 2026-04-15 8.6 High
This vulnerability affects NeuVector deployments only when the Report anonymous cluster data option is enabled. When this option is enabled, NeuVector sends anonymous telemetry data to the telemetry server. In affected versions, NeuVector does not enforce TLS certificate verification when transmitting anonymous cluster data to the telemetry server. As a result, the communication channel is susceptible to man-in-the-middle (MITM) attacks, where an attacker could intercept or modify the transmitted data. Additionally, NeuVector loads the response of the telemetry server is loaded into memory without size limitation, which makes it vulnerable to a Denial of Service(DoS) attack
CVE-2025-2183 1 Palo Alto Networks 1 Globalprotect App 2026-04-15 N/A
An insufficient certificate validation issue in the Palo Alto Networks GlobalProtect™ app enables attackers to connect the GlobalProtect app to arbitrary servers. This can enable a local non-administrative operating system user or an attacker on the same subnet to install malicious root certificates on the endpoint and subsequently install malicious software signed by the malicious root certificates on that endpoint.
CVE-2024-37311 2026-04-15 8.2 High
Collabora Online is a collaborative online office suite based on LibreOffice. In affected versions of Collabora Online, https connections from coolwsd to other hosts may incompletely verify the remote host's certificate's against the full chain of trust. This vulnerability is fixed in Collabora Online 24.04.4.3, 23.05.14.1, and 22.05.23.1.